爱克赛蓄电池容量怎么去测量

发布时间:2019-10-29人气:8

用放电叉测量爱克赛蓄电池电容量。放电叉是一支3V电压表和一个定值负载电阻并联装在一个带柄叉中的放电计,它只能检查爱克赛 蓄电池的一个单格(2V)。检测时,将两针抵牢一个单格的正负电桩,在指针稳定的3~5s内迅速读出所指示的放电数值。指示在1.75V以上,说明该格完全符合标准;指示在1.75~1.5V之间,应当及时充电;指示在1.5V以下,说明爱克赛 蓄电池有故障应予排除。

Measure the capacitance of Axel battery with discharge fork. The discharge fork is a 3V voltmeter and a constant load resistance installed in parallel in a fork with handle. It can only check a single cell (2V) of the axel battery. During the detection, two pins are pressed against a single positive and negative electric pile, and the indicated discharge value is read out quickly within 3-5s when the pointer is stable. If the indication is more than 1.75v, it means that the grid completely meets the standard; if the indication is between 1.75v and 1.5V, it should be charged in time; if the indication is less than 1.5V, it means that there is a fault in the axel battery that should be eliminated.